Electrical single line diagrams that design and check themselves

For houses and solar PV systems. Every circuit, cable and breaker sized and checked, with options compared on cost, losses and safety.

Two-storey villaStandard package · 3-phase 230/400 V 60 Hz · IEC 60364 · TN-S · max demand 44.5 kWUtility supplykWhMeterMain 100 A35 mm² Cu · 15 mMDB · Main board · 48-module (42 % spare)Surge protector Type 2M.1 · 10 A MCB R1 · 2.5 mm² · L1Water transfer pumpM.2 · 10 A RCBO · 2.5 mm² · L3Gate motorM.3 · 10 A RCBO · 1.5 mm² · L2Outdoor lighting3P 50 A · 10 mm² Cuto DB-1 Ground floor board3P 32 A · 4 mm² Cuto DB-2 First floor board1P 20 A · 2.5 mm² Cuto DB-3 Roof boardReserved: 6 modulesFrom main board3P 50 A · 10 mm² Cu · 8 mDB-1 · Ground floor board · 72-module (38 % spare)1.1 · 10 A MCB R1 · 1.5 mm² · L2Lighting 1 – Majlis, Living room1.2 · 10 A MCB R1 · 1.5 mm² · L3Lighting 2 – Dining, Kitchen, Guest bat…1.3 · 16 A RCBO · 2.5 mm² · L1Sockets 1 – Majlis1.4 · 16 A RCBO · 2.5 mm² · L1Sockets 2 – Living room1.5 · 16 A RCBO · 2.5 mm² · L2Sockets 3 – Dining, Guest bathroom, Bat…1.6 · 16 A RCBO · 2.5 mm² · L3Sockets 4 – Entrance & stairs1.7 · 20 A RCBO · 2.5 mm² · L2Kitchen sockets 1 – Kitchen1.8 · 16 A RCBO · 2.5 mm² · L2Outdoor sockets – Garden1.9 · 16 A MCB R1 · 2.5 mm² · L2AC 2 TR – Majlis1.10 · 16 A MCB R1 · 2.5 mm² · L1AC 2 TR – Living room1.11 · 16 A MCB R1 · 2.5 mm² · L2AC 1 TR – Dining1.12 · 16 A MCB R1 · 2.5 mm² · L3AC 1 TR – Kitchen1.13 · 16 A MCB R2 · 2.5 mm² · L1AC 1 TR – Maid / driver room1.14 · 16 A RCBO · 2.5 mm² · L1Water heater 11.15 · 16 A RCBO · 2.5 mm² · L2Water heater 21.16 · 16 A RCBO · 2.5 mm² · L3Water heater 31.17 · 16 A RCBO · 2.5 mm² · L3Oven1.18 · 32 A RCBO · 6 mm² · L3Cooktop1.19 · 16 A MCB R2 · 2.5 mm² · L1Dishwasher1.20 · 10 A MCB R2 · 2.5 mm² · L2Fridge / freezer 11.21 · 10 A MCB R2 · 2.5 mm² · L3Fridge / freezer 21.22 · 10 A MCB R2 · 2.5 mm² · L3Router / CCTV / securityFrom main board3P 32 A · 4 mm² Cu · 14 mDB-2 · First floor board · 48-module (25 % spare)2.1 · 10 A MCB R1 · 1.5 mm² · L2Lighting 1 – Master bedroom, Bedroom 2,…2.2 · 10 A MCB R1 · 1.5 mm² · L1Lighting 2 – Family room, Laundry, Corr…2.3 · 16 A RCBO · 2.5 mm² · L3Sockets 1 – Master bedroom2.4 · 16 A RCBO · 2.5 mm² · L1Sockets 2 – Bedroom 2, Bedroom 32.5 · 16 A RCBO · 2.5 mm² · L1Sockets 3 – Bedroom 4, Master bathroom,…2.6 · 16 A RCBO · 2.5 mm² · L2Sockets 4 – Family room, Laundry2.7 · 16 A RCBO · 2.5 mm² · L2Sockets 5 – Corridor & stairs2.8 · 16 A MCB R1 · 2.5 mm² · L2AC 1.5 TR – Master bedroom2.9 · 16 A MCB R1 · 2.5 mm² · L3AC 1 TR – Bedroom 22.10 · 16 A MCB R1 · 2.5 mm² · L1AC 1 TR – Bedroom 32.11 · 16 A MCB R1 · 2.5 mm² · L3AC 1 TR – Bedroom 42.12 · 16 A MCB R2 · 2.5 mm² · L3AC 1.5 TR – Family room2.13 · 16 A RCBO · 2.5 mm² · L2Water heater 12.14 · 16 A RCBO · 2.5 mm² · L3Water heater 22.15 · 16 A RCBO · 2.5 mm² · L2Water heater 32.16 · 16 A RCBO · 2.5 mm² · L1Washing machine2.17 · 16 A MCB R2 · 2.5 mm² · L1DryerFrom main board · on L21P 20 A · 2.5 mm² Cu · 20 mDB-3 · Roof board · 18-module (33 % spare)3.1 · 10 A MCB R1 · 1.5 mm² · L2Lighting 1 – Roof terrace, Roof store3.2 · 16 A RCBO · 2.5 mm² · L2Sockets 1 – Roof store3.3 · 16 A RCBO · 2.5 mm² · L2Outdoor sockets – Roof terrace3.4 · 10 A MCB R1 · 2.5 mm² · L2Water booster pumpSingle line diagram · WiseSLDTwo-storey villaStatus0 fail · 2 warn · 31,048 SARMCB with R1, R2… = protected by shared RCD group. Circle = RCBO (own 30 mA RCD). Red = check failed. Dashed = reserved space.
22 roomson 3 floors entered
44.5 kWmaximum demand → 100 A service
46 circuitssized on 4 boards
0 failedchecks on the Standard option

Part of the drawing WiseSLD produces for its built-in sample villa. Figures use the tool's typical default values.

What WiseSLD does

Project types: House / villa (all plans) · Solar PV (Starter and up) · Apartment building and Commercial (Pro, coming soon) · Industrial (Max, coming soon)

Enter the rooms floor by floor, or upload the floor plan. WiseSLD suggests the appliances, sizes the air conditioning, works out the maximum demand and the service to request, then designs every board and circuit.

Design a house
  • Load and maximum demand with every assumption listed
  • Circuits grouped, cables and breakers sized, phases balanced
  • Earth-leakage and surge protection, essential-loads board for backup
  • Economy, Standard and Future-ready options side by side
  • Board schedules and a priced bill of quantities

A villa, from rooms to drawing

The design story of WiseSLD's sample: a two-storey villa with a roof, in Riyadh. Every number below comes from the tool.

1 · Tell it about the house

Rooms, not formulas

The owner or contractor lists the rooms on each floor. WiseSLD fills in typical sizes, sockets and air conditioning for the climate, and suggests the appliances: a water heater for every bathroom, cooking in the kitchen, pumps on the roof.

Ground floorMajlisLiving roomDiningKitchenGuest bathroomBathroom 2Maid roomMaid bathroomEntrance & stairsGarden First floorMaster bedroomBedroom 2Bedroom 3Bedroom 4Master bathroomBathroom 3Bathroom 4Family roomLaundryCorridor & stairs RoofRoof terraceRoof store

2 · It works out the load

66 kW connected, 44.5 kW at peak

Not everything runs at once. WiseSLD applies diversity per type of load, shows every factor it used, and recommends the supply: here a 100 A three-phase service, with the phases balanced within 7 %.

Air conditioning15.6 kW
Sockets14.2 kW
Water heating12.0 kW
Cooking10.0 kW
Appliances7.5 kW
Lighting3.8 kW
Pumps & motors3.1 kW

44.5 kW maximum demand → 100 A three-phase

3 · Every circuit has a reason

No black box

Each of the 46 circuits shows how it was sized: the load, the current, the breaker, the cable after derating for heat, and the voltage drop from the meter to the last point. Tap "why" on any circuit to read the reasoning.

Circuit 1.9 · Ground floor board

Circuit
AC 2 TR – Majlis
Load
2.4 kW · 11.6 A
Breaker
16 A MCB
Cable
3 × 2.5 mm² Cu
Phase
L2
Voltage drop
2.66 % of 5 %

Why: a 2 TR unit draws about 2.4 kW, 11.6 A. The breaker is sized at 1.25 × running current for compressor starting, so 16 A.

4 · You choose, with the numbers in front of you

Three options, every trade-off visible

One board or one per floor? Shared RCDs or one per circuit? Space for solar and an EV charger? WiseSLD prices each choice and shows what it changes, then recommends one with a plain reason.

A · Economy26,774 SAROne RCD trip: 8 circuits
B · Standard31,048 SAROne RCD trip: 6 circuits
C · Future-ready38,903 SAROne RCD trip: 1 circuit

5 · The drawing set

Ready for review and the site

Single line diagram for every board, board schedules, load and demand calculation, cable schedule and a bill of quantities in your currency, all updated the moment anything changes.

  • Single line diagram, SVG and PNG
  • Board schedules with breaker, RCD and cable for each circuit
  • Load, diversity and maximum demand
  • Priced bill of quantities
  • Design report with every check

Why WiseSLD

Thinks like an engineer

It follows the real sequence: brief, loads, demand, supply, distribution, circuits, protection, options.

Explains every choice

Each breaker and cable comes with its reason, so a reviewer can check the logic, not just the result.

Shows the trade-offs

Cost, energy losses and what one fault switches off, for every option, before anything is bought.

International from day one

IEC 60364 or BS 7671, with country presets for voltage, frequency, earthing and temperature.

Your prices, your currency

Enter your supplier's rates and the bill of quantities follows every change.

Honest about its limits

Every assumption is listed. Fault level and loop impedance are flagged for site testing, and final drawings go to a licensed engineer.

Compared with designing by hand

TaskSpreadsheet and drawing by handWiseSLD
Load and maximum demandTyped in, diversity applied by handFrom rooms and appliances, factors shown
Cable and breaker per circuitLooked up one circuit at a timeAll circuits sized and re-checked on every change
Voltage drop to the last pointOften checked only on long runsChecked for every circuit, from the meter
Comparing optionsA second design for each optionThree packages plus each choice priced
Drawing and schedulesRedrawn after each changeRegenerated instantly

Plans

Free

$0
to try it
  • 1 house, up to 3 levels
  • Standard option only
  • PNG download with a WiseSLD watermark
  • No bill of quantities or drawing reading
Try it free

Starter

$15
per month
  • Houses and solar PV
  • 5 active projects, 3 revisions each
  • All options, choice by choice
  • SVG, PNG and report, no watermark
  • Bill of quantities
  • 5 drawing or plan readings a month
Choose Starter
Most popular

Pro

$29
per month
  • Everything in Starter
  • Apartment buildings and commercial
  • Unlimited projects and revisions
  • PDF drawing set, Excel bill of quantities
  • Your own title block
  • 30 readings a month
Choose Pro

Max

$45
per month
  • Everything in Pro
  • Industrial projects
  • 3 users with shared projects
  • Company logo and branding
  • 100 readings a month
  • Priority support
Choose Max

Prices in US dollars, before tax. Yearly plans include 2 months free. Apartment buildings, commercial and industrial projects are being added; the plans that include them are marked in the app. Cancel any time; your projects stay readable.

Questions

Does WiseSLD replace an electrical engineer?

No. It produces a complete, checked design quickly, with every assumption listed. Construction drawings still need review and sign-off by a licensed engineer where local rules require it.

Which standards does it follow?

IEC 60364 and BS 7671 today, with country presets for voltage, frequency, earthing and temperature. NEC is planned next.

What does it not check yet?

Prospective fault current, earth fault loop impedance and disconnection times depend on the utility supply and must be measured on site. WiseSLD lists them in every report.

Can I use my own prices?

Yes. Every rate in the bill of quantities is editable, in any currency.

Who can see my projects?

Only you, and the people you share a project with on the Max plan.

What can I do on the Free plan?

Design one house of up to three levels and see the Standard option, with a watermarked PNG of the drawing. Other options, the bill of quantities, downloads without a watermark and drawing reading come with Starter.

What happens if I cancel?

Your account moves to the Free plan. All projects stay readable; you can edit one.